3 INSTALLATION AND CONNECTION

3.1 MECHANICAL INSTALLATION

3.1.1 Installation Environment

Avoid installing the inverter in an area with:
Direct exposure to sunlight, rain, high humidity, or sea-air.
Inflammable or corrosive gases or liquids.
Excessive vibration.
Dust, metallic particles, and oil mist.
Environment conditions for the operation of the inverter:
Inverter surrounding temperature: from -10 ºC up to Ta according to the
152.
For temperatures around the inverter greater than Ta and smaller than 60 °C (140 °F) (frame
sizes A, B, C and D), 40 °C (104 °F) (models with degree of protection IP55) and 55 °C (133 °F)
(frame size E), it is necessary to apply current reduction of 2 % for every degree Celsius (or
1.11 % each °F) up to Ta.
Humidity: from 5 % to 95 % non-condensing.
Altitude: up to 1000 m (3.300 ft) - standard conditions (no derating required).
From 1000 m to 4000 m (3.300 ft to 13.200 ft) - current derating of 1 % each 100 m (or 0.3 %
each 100 ft) above 1000 m (3.300 ft) altitude.
From 2000 m to 4000 m (6.600 ft to 13.200 ft) above sea level - maximum voltage reduction
(240 V for 200...240 V models, 230 V for 220...230 V models, 480 V for 380...480 V models
and 600 V for 500 ...600 V models) of 1.1 % for each 100 m (330 ft) above 2000 m (6.600 ft).
Pollution degree: 2 (according to EN50178 and UL508C) with non-conductive pollution.
Condensation shall not originate conduction through the accumulated residues.

3.1.2 Mounting Considerations

External dimensions, fixing holes position and net weight of the inverter are presented at
B.2 on page 169
and
Figure B.10 on page 178
Install the inverter upright on a flat surface. First place the screws on the surface where the
drive is going to be installed, install the drive and then tighten the screws.
Frame size E inverters with N1 option (CFW701E...N1...):
After fixing the inverter, install the upper Nema 1 kit on the inverter using the two M8 screws
provided with the product.
Figure B.3 on page
171. Please refer to
for more details of each inverter frame size.
Installation and Connection
Table B.4 on page
Figure B.4 on page 172
CFW701 | 9