13. Clean the Inlet Screens
Disconnect the power and turn off the water supply.
Disconnect and remove the removable pipe segment.
Using a screwdriver, remove the inlet clamp screws.
Remove the inlet clamp.
Remove the adapters from the valve inlets.
Gently pull the check valves from the valve inlets.
Remove the screens from the check valves.
Clean the screens to remove any dirt or debris.
Rinse or replace the check valves and screens.
Reassemble the inlet connections.
14. Troubleshooting
CAUTION: Risk of personal injury. The valve may contain hot water; be careful when draining any
residual water.
IMPORTANT! Turn off the power and water supply to the valve before performing any maintenance.
It is recommended that any valve maintenance should be performed by an authorized Kohler service
representative.
This troubleshooting guide is for general aid only. For service and installation issues or concerns, call
1-800-4-KOHLER.