Setting Up The Pneumatic Motor En - Binzel Abicor BRS LCi Instructivo De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BRS LCi PLC
6.7 Setting up the pneumatic motor
NOTICE
The cleaning station must be and remain without compressed air and tension during setup!
• The clamping prism diameter must match that of the gas nozzle.
• The distance sleeve must match the nominal diameter of the gas nozzle.
• The reamer must be precisely aligned with the torch type.
1
Clamping device
2
Gas nozzle
Fig. 11
Setting up the pneumatic motor
 Fig. 7 Putting into operation on page EN-13 and Fig. 11 Setting up the pneumatic motor on page EN-17
1 Use the screws (3) to loosen the pneumatic motor from the guide block (4).
2 Pull back the pneumatic motor (5) in its fastener.
3 Place the required distance sleeve (7) on the reamer (6).
4 Move the torch with the gas nozzle (2) to the clamping position (P2).
5 Keep the guide block (4) in the lower position (stroke down).
6 Place the pneumatic motor (5) with the distance sleeve (7) attached against the gas nozzle (2).
7 Secure the motor in the set position using the screws (3).
8 Move the torch out of the clamping device (1) and remove the distance sleeve (7) from the reamer (6).
NOTICE
• Make sure that only clean and dry compressed air is used.
The compressed air must be of quality class 4 according to ISO 8573-1 as a minimum.
BAL.0424.0 • 2019-04-23
1
7
6
5
3
Screws
5
4
Guide block
6
6 Putting into operation
2
3
4
Pneumatic motor
7
Distance sleeve
Reamer
EN - 17