Wiring Diagrams - Eaton POTFOLIO IB520022EN Instrucciones De Instalación

Luminarias led empotradas de uso comercial para áreas ocultas ldsq4b y ldsq6b
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instructions – LDSQ4B/LDSQ6B Commercial Recessed LED Rough-In
2.
Remove junction box cover (Figure 12.).
3.
Remove appropriate round pryout and connect conduit
to junction box with proper connector (not included).
4.
Connect supply lead wires to junction box lead wires
(line, neutral and ground) in the fixture using the
provided lever nut connectors. (Figure 14). Be careful
not to leave any bare conductors outside of the lever
nut connectors.
5.
Lift the orange tab on the lever nut to disengage the
wire and close to secure the wire in place. (Figure 14).
6.
Connect white to white, black to black, and green
(from electrical service) on the supply side to the bare
copper wire in the junction box. Place all excess wiring
and connections into the junction box and replace the
cover. Place all connections and excess wiring into the
junction box and replace cover.
Driver Replacement
CAUTION
To avoid possible electrical shock, be sure that the power is
turned off before installing or servicing this fixture.
• The driver should be replaced by a qualified electrician.
• The driver may be replaced either from below or above the
ceiling.
1.
Remove trim assembly from the housing (Figure 9.).
2.
Remove the driver and junction box cover assembly.
(Figure 13.).
3.
Disconnect the wiring to the driver by undoing the lever
nut connectors then cut the red and blue wires.
4.
Discard the old driver and junction box cover assembly.
5.
Connect the new driver leads with the lever nut
connectors.
6.
Reattach the new driver and junction box cover
assembly.
Figure 12
4
Installation Instructions – LDSQ4B/LDSQ6B Commercial Recessed LED Rough-In www.eaton.com
Driver
Figure 13
Lever Closed
Close Lever To
Secure Wire
Figure 14

Wiring Diagrams

1.
For D010
BLACK (LINE)
BLACK (LINE)
0-10V DIMMING
WHITE
WHITE
DRIVER
(NEUTRAL)
(NEUTRAL)
GROUND
Lever Open
Open Lever To
Release Or Insert
Wire
RED
RED
BLUE
LED
PURPLE
BLACK
GRAY
MOUDLE WIRING
DIAGRAM
0-10V
DIMMING
OPTION
(FIELD
INSTALLATION)

Publicidad

Tabla de contenido
loading