LED engine with slot on trim assembly (Figure 6.).
3.
Rotate side clips (3) into place to securely attach trim
assembly to LED engine (Figure 7 .).
4.
Properly align the connector as shown in (Figure 8.).
Plug in the luminaire quick disconnect on the module.
5.
Find the green ground wire inside cylinder and attach it
to the heatsink screw boss,using the lockwasher and
screw provided (Figure 9.).
6.
Install the LED Engine and trim assembly by inserting
the torsion springs into the spring receivers located
inside the housing (Figure 10.).
Cleaning
To Clean Trims:
1.
Gently wipe with soft, clean, dry lint-free cloth to
remove dust.
2.
Wipe with mild detergent solution on a soft, clean cloth
to remove fingerprints and stains.
3.
Rinse with clean water and dry with soft, clean, dry
lint-free cloth.

Electrical Connection

CAUTION
Make certain no bare wires are exposed outside of wire nut
connectors.
1.
Provide electrical service according to the "National
Electrical Code" or your local electrical code to the
cylinder housing assembly. Supply wire insulation must
be rated for at least 90°C.
2.
Connect supply lead wires to cylinder housing lead
wires (line, neutral and ground) in the fixture using
properly sized wire nuts. Be careful not to leave any
bare conductors outside of the wire nut connectors.
3.
Connect white to white, black to black, and green (from
electrical service) on the supply side to the green
wire in the cylinder housing assembly.
Figure 7.
Installation Instructions – LSR4B / LSSQ4B Commercial LED Rough-In
Installation Instructions – LSR4B / LSSQ4B Commercial LED Rough-In
IB520036ML
Figure 8.
Figure 9.
Figure 10.

Wiring Diagrams

1. For D010TR Driver
BLACK (LINE)
BLACK (LINE)
TRIAC DIMMING
@120VAC
WHITE
WHITE
OR 0-10V @
(NEUTRAL)
(NEUTRAL)
120-277VAC
DIMMING
DRIVER
GRN
www.eaton.com
Screw
Green
Ground
Wire
Lockwasher
Heatsink
Screw Boss
BLUE
BLACK
RED
LED
PURPLE
RED
GRAY
MODULE WIRING
DIAGRAM
0-10V DIMMING
OPTION (FIELD
INSTALLATION)