7. Electrical connections
Before connecting the power supply, make sure the plate data correspond to that of the mains
power supply.
An omnipolar disconnection switch with minimum contact gaps of 3 mm must be included in the
mains supply.
Check that upstream of the electrical installation there is an adequate residual current circuit
breaker and a suitable overcurrent cutout.
The gearmotors OBB13BH-OBB13BFCH can be connected to the E2HOB control panel.
The electrical wiring and the start-up of the gearmotors OBBI3BH and OBBI3BFCH are shown in
figure and in the installation manuals of the E2H control panel.
E2HOB control panel terminal board
Motor 1
31
OBBI3BH
Blue
OBBI3BFCH
Brown
E2HOB control panel terminal board
Motor 2
34
OBBI3BH
Black
OBBI3BFCH
White
E2HOB control panel terminal board
Motor 1
31
OBBI3BH
Black
OBBI3BFCH
White
E2HOB control panel terminal board
Motor 2
34
OBBI3BH
Blue
OBBI3BFCH
Brown
35
32
33
/
Black
Green
White
35
36
/
Blue
Green
Brown
32
33
/
Blue
Green
Brown
35
36
/
Black
Green
White