13. Electrical connections TOP603H

Installation, electrical connections and adjustments must be performed by qualified person-
nel, in accordance with Good Working Methods and in compliance with the current regulations.
The automation must be installed in compliance with Standards EN 12453, EN 12445 and EN
12635. The safety devices must be working properly.
Garages without a second entrance must be equipped with an external emergency release device
(to be ordered separately).
If there is a pedestrian door incorporated into the garage door, it must be equipped with a safety
device that prevents it being activated when the garage door is open.
be connected to the EMERGENCY STOP.
In the external automation section, the connections to the mains power supply and any
other low voltage wires (230V) must be made on an independent channel separated from
the connections to the command and safety devices (SELV = Safety Extra Low Voltage).
F1.6AT line
1 2 3
4 5
N
Power supply
Y E L L
O W
G R E
E N
24V~ 0V 24V~
6
7
Power unit
L PE
STOP
8
9 10
24V
Motor
71
This safety device must
SIG
Antenna
GND
Step by step