EHEIM LOOPpro 6000 Manual De Instrucciones página 14

Ocultar thumbs Ver también para LOOPpro 6000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
English
‧ When the UVC clarifier is fitted, the device's safety distance from the
water must be at least 2 m.
4.
Commissioning
Removing the filter container cover (⌦A)
1. Press in the lower part of both side locks with your fingers (⌦A1) and pull the upper part with your
thumbs at the same time (⌦A1).
2. Lift the filter container cover off the filter container (⌦A2).
3. Remove all components from the filter container.
Fitting the backwash connecting piece (⌦B)
1. Fit the flat seal ② onto to backwash connecting piece ①.
2. Insert the backwash connecting piece from the inside through the opening in the filter container.
3. Fasten the backwash connecting piece with the union nut ③.
4. Insert the sealing washer ④ into the plug ⑤.
5. Seal the backwash connecting piece with the plug.
Fitting the outlet funnel (⌦C)
1. Check the correct fit of the seal ① in the outlet funnel ②.
2. Slip the sealing ring ③ onto the outlet funnel.
3. Insert the outlet funnel from the inside through the opening in the filter container.
4. Fasten the outlet funnel with the union nut ④.
Fitting the UVC clarifier (⌦D/E)
1. Slip the sealing washer ② onto the thread of the UVC clarifier.
2. Insert the UVC clarifier through the opening in the filter container.
3. Fasten the UVC clarifier with the union nut ①.
4. Insert the screw ④ with the O-ring ⑤ from the inside through the hole in the mounting bracket of the
UVC clarifier.
5. Screw the UVC clarifier tight with the nut ⑦ and the washer ⑥.
Fitting the hose connecting piece (⌦F)
1. Slide the union nut ③ onto the hose connecting piece ②.
2. Insert the seal ① into the union nut.
3. Screw the hose connecting piece onto the UVC clarifier with the union nut.
Inserting the filter (⌦G)
1. Check that the seal ⑤ is correctly seated in the pre-filter tray ③.
2. Insert the filter in the filter housing in the following order:
① Filter insert with filter foams
② Bioballs
Make sure that there are no bioballs on the outlet funnel (⌦E)!