6
Wiring the device modules
Safety modules
Displays
Pos.
MS
EN
ME
PS
DE
86
Colour
State
On
Blinking
Green
Off
On
Yellow
Off
On
Blinking
Red
Flashing
Off
On
Red
Blinking
Off
Red
On
Description
Drive-based safety is initialised faultlessly.
Drive-based safety is initialised faultlessly. Internal
communication to the standard device is not possible.
Drive-based safety is not initialised.
Acknowledgement is not possible.
Controller enabled
Non-safe display "STO"
System error:
After a serious internal error, STO is activated.
Can only be reset by switching the 24V supply.
Error:
After an internal error or an error at the safe inputs, a
standstill function is activated.
The safety class is quit.
Acknowledgement is possible.
Fault:
A monitoring function has responded and activated a
standstill function.
The safety class is not quit.
Acknowledgement is possible.
Error-free operation
Error PROFIsafe:
Communication is not possible.
Acknowledgement is possible.
No valid PROFIsafe configuration
PROFIsafe is error-free.
The module is not accepted by the standard device (see notes
given in the documentation for the standard device).
EDK94SH104 DE/EN/FR/ES/IT 4.1