Start-up
Main switch
9
for turning the welding machine ON
and OFF.
Turning knob for setting material
45
thickness/welding voltage/welding
step.
Key button secondary parameter
46
to access the secondary parameter
menu. When within this menue this
key serves to end it.
47
Trigger Mode
to select 2-stroke, 4-stroke, spot weld-
ing or interval mode.
Key button menu
48
to access the main menu. Pressing
this key will move one level back.
Graphic display
49
displays all information in clear text.
Key Tiptronic/characteristics
50
direct access to the Tiptronic menu
alt. characteristics menu (if Tiptronic is
switched off).
Key Secondary parameter
51
access the secondary parameter di-
rectly. Within the menu press this key
to end menu.
52
Operation knob Menu
Turning knob wire feed serves to:
select menu (turn)
confirm menu option (press)
setting wire feed
setting secondary parameter
Display mode
55
displays the selected mode by sym-
bol.
Display characteristics
56
displays the set characteristic line.
Display Tiptronic-Job
57
if the job no. is followed by an asterisk
(*) on the display, a min. parameter of
a saved job has been changed.
10.13
Dispay wire feed correction
58
displays the wire feed as correction
value differing from the characteristic
line in %.
Display wire feed
59
displays the actual wire feed speed in
m/min.
Display welding step
60
displays the selected welding step.
Display material thickness
61
displays the selected material thick-
ness of the workpiece in mm.
Display welding voltage
62
displays the selected welding voltage
in Volt.
13.2 Start-up
 Select with mode key 47 the 2-stroke
mode.
 Press key characteristics 50 to enter
menu characteristics.
 Set matching charateristic line (material-
gas-wire combination) by turning opera-
tion knob 52.
 Confirm the characteristic line by press-
ing operation knob 52.
 Press operation knob 52 again to end
menu and return to standard display.
 Set the required material thickness alt.
welding step by using turning knob 45.
9 The machine is ready for welding.
Use operation knob 52 to correct the wire
feed if needed.
- 47 -