Dräger PIR 7000 Instrucciones De Uso página 398

Ocultar thumbs Ver también para PIR 7000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 48
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com
Certificate No.:
IECEx UL 07.0009X
Status:
Current
Date of Issue:
2014-12-14
Dräger Safety AG & Co. KGaA
Applicant:
Revalstrasse 1
D-23560 Lübeck
Germany
Electrical Apparatus:
Gas Sensor Type IDS 01xx*
Optional accessory:
Type of Protection:
Flameproof "d"
Marking:
Ex d IIC T6/T4 Gb
T6: -40°C Tamb
T4: -40°C Tamb
Approved for issue on behalf of the IECEx
Certification Body:
Position:
Signature:
(for printed version)
Date:
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the
Certificate issued by:
UL LLC
333 Pfingsten Road
Northbrook IL 60062-2096
United States of America
398
IECEx Certificate
of Conformity
issue No.:3
Certificate history:
Issue No. 3 (2014-12-
14)
Issue No. 2 (2012-10-
26)
Page 1 of 4
Issue No. 1 (2011-9-4)
Issue No. 0 (2007-10-4)
+40°C
+80°C
Paul T. Kelly
Principal Engineer - Global Hazardous Locations
2014-12-14
Official IECEx
Website.
IECEx Certificate
of Conformity
Certificate No.:
IECEx UL 07.0009X
Date of Issue:
2014-12-14
Manufacturer:
Dräger Safety AG & Co. KGaA
Revalstrasse 1
D-23560 Lübeck
Germany
Additional Manufacturing location
(s):
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and
found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products
covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This
certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents
as amended.
STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified
documents, was found to comply with the following standards:
IEC 60079-0 : 2011
Explosive atmospheres - Part 0: General requirements
Edition: 6.0
IEC 60079-1 : 2007-04
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Edition: 6
IEC 60079-1 : 2014-06
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Edition: 7.0
This Certificate does not indicate compliance with electrical safety and performance requirements other than those
expressly included in the Standards listed above.
TEST & ASSESSMENT REPORTS:
A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in
Test Report:
US/UL/ExTR07.0014/00
US/UL/ExTR07.0014/01
US/UL/ExTR07.0014/03
Quality Assessment Report:
DE/BVS/QAR06.0001/09
Issue No.: 3
Page 2 of 4
US/UL/ExTR07.0014/02

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pir 7200

Tabla de contenido