36
SELECTION OF EQUIPMENT
This device should only be used in the following circumstances:
Factors/circumstances constituting respiratory hazard cannot be eliminated by other means.
A suitable and sufficient risk assessment has been carried out which identifies the hazards present
and the level of risk.
The risk assessment should identify:
The hazardous substances/chemicals present in the atmosphere, their physical state (liquid, vapour,
solid, gas), and likely levels of contamination.
Other hazards in the workplace, e.g. flying or falling solid objects, liquid splashes, molten, metal
splashes, potentially explosive atmospheres, noisy environments, UV, IR radiation etc.
Wearer factors such as medical fitness, beards or spectacles
Job/task factors such as required mobility, workrate, tools to be used, other PPE to be used (e.g.
protective clothing).
Environmental factors such as temperature, humidity or high winds.
Useful information:
prEN529
BS4275:1997
ZH1/701, publisher HVBG (Germany).
Selection of blower-assisted breathing protector equipped with filter
See Instructions for Use of the blower device to be used.
Type of protective device
Power-assisted face shield with
particle filter
TH1P
TH2P (Procap)
TH3P
Device with combined filter
Power-assisted face shield with
gas filter *)
TH1 gas filter class 1 or 2
TH2 gas filter class 1 or 2
TH3 gas filter class 1 or 2
Compressed air line breathing
apparatus with face shield and T/A/
LINE
*) Provided that the maximum permissible detrimental gas concentration for the gas filter is not exceeded. For
power-assisted filtering devices with gas filter, concentration must not exceed 0.05 vol.% in gas filter class 1 and
0.1 vol.% in gas filter class 2 and 0.5 vol.% in gas filter class 3.
**) If national guidelines exist: in all cases the lowest value applies.
PACKING FOR SHIPMENT
For shipping, the Procap should be placed into its original packaging or a similar cardboard carton.
Multiples of threshold concentration **)
APF (Assigned protection factor)
BS 4275 (GB)
BGR 190-ZH1/701 (DE)
10
5
20
20
40
100
The specified multiples of threshold value for the gas or particle filters
are given separately, but in all cases the lowest value applies.
10
5
20
20
40
100
20
100
Remarks, limitations
"Open" facepieces, such as helmets or hoods,
do not provide sufficient protection in case of
breakdown or inferior output of the blower.
Therefore, devices of class TH1 must never
be used against carcinogenic, very poisonous
or radioactive gases and vapours.
For devices with combined filter apply the
relevant limitations of gas and particle filters.