Check by-pass setting
D
Note: The by-pass has been factory set at 30%.
Engage the fi lter head
4.2 Setting By-Pass and Capacity
Identify the carbonate hardness of the local water using the BRITA carbonate hardness test
(Art. 710800). Alternatively, the local water supplier will provide information on carbonate hard-
ness.
Determine the by-pass setting and capacity according to the application and the carbonate hard-
ness identifi ed using the by-pass and capacity tables (Chapter 6).
Then turn the by-pass setting
Note: Only the PURITY C 0–70% fi lter head has a variable by-pass setting. Installation of the
BRITA FlowMeter 10–100A (Art. 298900) is recommended for the precise, continuous control
of the degree of fi lter cartridge exhaustion.
4.3 Inserting the Filter Cartridge
Remove protective cap
E
Note the next exchange date in the date fi eld on the fi lter cartridge
Insert the fi lter cartridge
F
Caution: The fi lter cartridge can only be inserted when the locking handle is open.
!
Make sure that the fi lter cartridge is positioned correctly.
Turn the locking handle
4.4 Commissioning
Open the water intake and switch on the power supply of the terminal equipment.
G
Operate the fl ush valve
bubbles. At least 2 empty fi lter cartridge volumes must be fl ushed (Chapter 9).
H
Note: When bleeding/fl ushing, catch water emerging from the fl ush hose
appropriate container.
Check system for any leaks.

5 Exchanging the Filter Cartridge

The fi lter cartridge must be replaced after 6–12 months, at the latest 12 months after commission-
ing, irrespective of the level of exhaustion of the fi lter system. If the capacity of the fi lter cartridge
has already been exhausted (Chapter 6), it must be exchanged earlier.
Caution: During the exchange, carefully examine all dismantled parts! Faulty parts must be
!
exchanged and dirty parts should be cleaned. Read the Operating and Safety Information (Chapter 3)
prior to exchange. After storage and transport below 0°C the product must be stored in the open
original packaging for at least 24 hours at the stated ambient temperatures (Chapter 9) for operation.
Note: When the locking handle is open, the water supply to the cartridge is interrupted and short-
circuit operation with direct water fl ow from the water inlet
sary, close the water supply and switch off the power supply to the downstream appliance).
Open locking handle
Activate the fl ush valve
Remove exhausted fi lter cartridge
Note: The fi lter cartridge can be pivoted by 90° in the wall mount for easy removal.
Perform the steps described at 4.3 and 4.4.
and, if necessary, adjust to local carbonate hardness (Chapter 4.2).
10
in the wall mount
1
to the identifi ed value.
10
.
7
vertically in the fi lter head
6
until you feel it engage.
2
and fi lter system until the fi ltered water runs clear and without
8
.
2
and remove pressure from the system.
8
from the fi lter head
6
.
5
.
1
to the outlet
4
3
.
1
.
6
in an
9
is possible (if neces-
13