Home S Ec U R I T Y C O Nnect Ion; Plumbing; Preparation; Anti-Tip Bracket - Sub-Zero ICBIW-30C Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
SIT E P R E PAR AT IO N
Electrical

HOME S EC U R I T Y C O NNECT ION

If the unit will be connected to a home security system, low-
voltage leads must be provided to the unit. Two connectors
are located behind the top trim. Provide 3 m minimum lead
wires for each connector, exiting the back wall near the
electrical receptacle.
Remove the top trim by disengaging the trim from the hinge
side of the unit. Rotate the trim and remove the trim pin from
the handle side vertical support. Refer to the illustrations
below. Use spade terminals or wire nuts to make proper
wiring connections. Refer to the following color codes:
Normally open contacts—white with red stripe wire.
Common—gray with white stripe wire.
CAUTION
The alarm circuit in the unit is intended as a low-
voltage, low-current device only. It should not be used
to switch line power. Any unused terminals should be
completely insulated and all wires should be secured
away from conductive or moving components.
PIN
Top trim—hinge side.
Top trim—handle side.
|
4
English

Plumbing

Installation must comply with all applicable plumbing
codes.
For model ICBIW-30CI, the water supply line should be
located within the shaded area shown in the illustration
below. The water supply line should be connected to the
house supply with an easily accessible shut-off valve. Do
not use self-piercing valves. The water supply line must be
flush to the floor and not interfere with installation of the

anti-tip bracket.

A reverse osmosis system can be used provided there
is constant water pressure of 2.4–8.3 bar supplied to the
unit at all times. A copper line is not recommended for this
application.
PLU MB I NG RE QUI REM ENT S
Water Supply Line
1
/
" OD copper, braided
4
stainless steel or PEX tubing
Water Pressure
2.4–8.3 bar
Excess Water Line for Connection
RIGHT SIDE
OF OPENING
152
152
mm
mm
76 mm
13 mm
AREA EXTENDS
FORWARD ON FLOOR
Water supply location
(ICBIW-30CI).

Preparation

Uncrate the unit and inspect for damage. Remove the wood
base and discard shipping bolts and brackets. Remove and
recycle packing materials. Do not discard the kickplate, anti-
tip bracket and hardware.
Remove the kickplate by extracting the two mounting
screws. Refer to the illustration below.
SCREW
.9 m
Kickplate removal.
Anti-Tip Bracket
WARNING
To prevent the unit from tipping forward, the anti-tip
bracket must be installed.
The back of the anti-tip bracket must be installed 610 mm
from the front of the unit (without panels). Use all anti-tip
bracket hardware as instructed for wood or concrete floors.
IMPORTANT NOTE:
For wood or concrete floor applications,
if the #12 screws do not hit a wall stud or wall plate, use the
#8 screws and #12 washers with the wall anchors.
IMPORTANT NOTE:
In some installations the subflooring or
finished floor may necessitate angling the screws used to
fasten the anti-tip bracket to the back wall.

Publicidad

Tabla de contenido
loading

Tabla de contenido