7.6 Valve Setup & Calibration
Menu location: Setup Menu
The Valve Setup screen contains information about the assigned valve, as well as options for calibration and other con-
figuration, which are organized into the following categories:
• Valve Assignment
• Valve Name
• Valve Calibration
• Valve Options
The Valve Setup screen also displays the currently assigned valve serial number (if any), as well as the assigned valve's
name and color (if any) on the bottom of the screen for informational purposes.
Valve Assignment:
The first time the valve and display are powered up together, the valve is assigned to a display . Details on this initial
setup can be found under "Assigning a Valve" in Section 6, "INITIAL SETUP", above. In the event the valve needs to be
assigned to another display or is incorrectly assigned to a display, this menu option allows the valve to be manually as-
signed to a valve .
If a display needs to be assigned to another valve (after it was initially assigned to a different valve) and there is only one
valve on the network, follow these steps:
1 . Connect the display to the new valve
2 . Apply power to the valve and the display
3 . Press the ■ ENTER button when prompted to Reassign Valve
4 . Press the ■ SET button to select the connected valve
5 . The controller will re-start and is now assigned to the new valve .
To manually assign the valve in a network installation, follow these steps:
1 . Navigate to the Valve Setup menu
2 . Press the ■ ENTER button to select "Valve Assignment"
3 . Press ■ OK to reassign the valve when prompted
4 . If more than one valve is connected to the network, a list of serial numbers will be displayed .
RED and
Use the
highlighted . Then press the ■ SET button to assign the selected valve .
5 . The controller will re-start and is now assigned to the new valve .
Valve Name:
The Valve Name menu has options for identifying a valve by a name, as well as a number and a color . The name, number
and color are all optional . If set, they will be displayed in a bar across the top of the screen during normal operation . The
number can be selected if there are multiple valves with the same name; for example, Crosslay 1, Crosslay 2, etc . The
name, number and color can also all be cleared so that nothing is displayed across the top of the display (this is the fac-
tory default).
To configure the Valve name, number and color, follow these steps:
1 . Navigate to the Valve Setup menu
2 . Use the
RED or
3 . Press the ■ ENTER button to select "Valve Name"
4 . Use the
RED or
assigned valve. In no name is desired, select "None."
5 . Press ■ SET to assign the name
6 . After the name is set, the Valve Number field will now be highlighted . Use the
select the desired number. If no number is desired, select "None."
7 . Press ■ SET to assign the number
8 . After the number is set, the available Valve Colors will be shown . Use the
the desired color. If no color is desired, select "White."
9 . Press ■ SET to assign the color .
OEM Configuration
→
→
GREEN buttons to scroll through the list until the desired valve serial number is
GREEN button to scroll through the list until the "Valve Name" is highlighted
GREEN button to scroll through the list and highlight the desired pre-loaded name for the
Valve Setup
Page 15
RED or
GREEN button to
RED or
GREEN button to select