21. USE AND CARE (
Avoid when choosing a detergent:
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be
used close to a range.
22. OPERATION
Always turn your blower on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear
the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
The insert is operated using the three slide controls located beneath the front edge of the insert or the WCPI optional wall control.
HC0009
COOKTOP LIGHTING (HALOGEN)
The light switch turns the halogen lights ON and OFF.
Use shielded halogen bulbs (120 V, 50 W, MR16 or PAR16 with GU10 base), included.
BLOWER
The blower is operated using 2 controls.
Use the blower speed control to increase or decrease cooktop ventilation. Slide the control to the left to increase the blower speed—to
the right to decrease the blower speed.
The blower ON/OFF switch turns the blower ON to the speed preset by the speed control. The blower must be turned ON and OFF using
this switch.
HEAT SENTRY™
This unit is equipped with a Heat Sentry thermostat. This thermostat is a device that will turn on or speed up the blower if it senses
excessive heat above the cooking surface.
1) If blower is OFF—it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting—it turns the blower up to HIGH speed.
The HEAT SENTRY can start the blower during a range top fire or other excessive heat situations even if the hood
is turned off. If this situation occurs, it is impossible to turn the blower OFF with blower switch. If you must stop
the blower, do it from the main electrical panel.
When the temperature level drops to normal, the blower will return to its original setting.
Test all insert switches. If a WCPI remote control is installed, test all its switches
WCPI REMOTE CONTROL (OPTIONAL)
An optional remote control is also available to operate your hood insert. For installation
details, see installation instructions included with the WCPI remote control.
NOTE: When the WCP1 remote control is connected to the insert, the control switches on
the insert are no longer operational.
'
)
CONT
D
1
1) Light switch
2
2) Blower speed control
WARNING
!
13
3
3) Blower ON/OFF switch
1 2
HC0006
1) Light switch
3) Blower speed control
2) Blower ON/OFF switch
3