Liberty Pumps Ascent II-ESW Manual De Instalación página 13

Ocultar thumbs Ver también para Ascent II-ESW:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4-3-7
Interconnect hose:
A hose connects the discharge of the motor cartridge (pump) to the discharge flange. To remove this hose, follow the
procedure to remove the discharge flange and motorized cartridge. Both ends of the hose are secured with clamps.
4-3-8
Control Switch:
The control switch cartridge is mounted to the main
cover with fasteners. The control has two power
cords, first is the main power cord that plugs into
the house receptacle and the other powers the
motorized cartridge. The motorized cartridge must
be removed to disconnect this cord. See
instructions under the heading "Accessibility to
Motorized cartridge 4-3-5" for details.
4-3-9
Toilet sealing ring:
The seal between the toilet and the macerator
consists of a rubber ring connected to the
macerator to which the toilet slides into. The rubber
ring stretches and forms a seal around the
discharge hub of the toilet. This rubber ring is
replaceable by unclipping the plastic retainer and
then pulling the ring outward. Installation is reverse,
first slide the rubber ring onto the macerator
followed by the retaining ring.