Liberty Pumps Ascent II-ESW Manual De Instalación página 63

Ocultar thumbs Ver también para Ascent II-ESW:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Troubleshooting
Symptoms
1. Poor flush.
2. No flush.
3. The fill valve turns on/off by itself without
the toilet being flushed, or it runs allowing
water to enter the tank.
4. Tank takes excessive time to fill.
5. There is excessive noise when the tank is
filling.
6. Trip arm strikes the tank lid underside.
7000 Apple Tree Avenue
Bergen, NY 14416
Phone: (800) 543-2550
Fax: (585) 494-1839
www.libertypumps.com
©Copyright 2011 Liberty Pumps Inc. All rights reserved.
Recommended Action
A. Adjust the tank water level to match the
waterline.
B. Fully open the water supply shut-off valve.
C. Clear obstructions from the trapway, jet, or
bowl rim holes.
D. Clear obstructions from the waste line.
A. Reconnect the flapper chain to the trip lever or
flush valve.
B. Adjust the flapper chain assembly to remove
excessive slack.
A. Adjust the flapper chain for proper slack so the
flapper closes.
B. Clean or replace the flapper if it is worn, dirty,
or misaligned with the opening.
C. Clean the area around the opening to allow
the flapper to seal.
D. Adjust the tank water level if it is too high.
E. Replace the fill valve if the valve float sinks.
A. Fully open the water supply shut-off valve.
B. Clean the valve inlet, valve head, or supply
line. Flush the lines.
A. Partially close the water supply shut-off valve
if the water pressure to the toilet is too high.
Check the toilet performance following any such
adjustment.
B. Remove dirt or obstructions from the valve
head. Flush the lines.
A. Adjust the chain to remove excessive slack.
8

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Ascent ii-rsw

Tabla de contenido