1.3 ELECTRICAL CONNECTION
WARNING!! The electrical connections for the machine
should only be carried out by a qualified technician who will
be in charge of the preparation of the installation and who
should follow the indications below before connecting to the
power supply.
- ENSURE that the power voltage and frequency correspond
to that given on the data plate fixed on the side of the machi-
ne Permitted Tolerances: +/- 10% of rated voltage +/-1% of
continuous rated frequency.
- IT IS IMPORTANT to connect the equipment to an efficient
earthing system, fitted according to the standards in force
WARNING!! Do not use sockets or plugs that are not been
earthed.
- IN ORDER to protect the equipment from possible overloa-
ds or short circuits, connection to the power supply must be
made by means of a thermomagnetic circuit breaker or a
switch with adequate dimensioned fuses.
- WE RECOMMEND, furthermore, that a differential switch
(earth fault interrupter), with a high-sensitivity of at least 30
mA and manual reset, be fitted upstream of the system.
CAUTION!! If the power supply is made by means of a generator make sure that the produced electrical energy is sufficient for
a sure start-up of the compressor.
For the size of safety device, the following should be taken into calculation:
-I n (rated current), indicated on the CE label, intervention curve "C"
-PROCEED to the electrical connection of the machine by following the colours of the wiring in the power supply cable:
green/yellow
=
PROTECTIVE CONDUCTING WIRE
blue
=
NEUTRAL
-POSITION the door microswitch on the upper corner of the door (hinged side).
-CONNECT the resistor (if foreseen) to the relative power supply cables of the machine.
WARNING!! In the event that it is necessary to extend the power supply cable and/or auxiliaries,
first contact our Technical Department.

1.3.1 DOOR SWITCH CONNECTION

Where required, connect the door switch as indicated in the electrical diagram. Some machines are supplied with a cable bridge
on the door switch terminals, this must be removed when a door switch is installed.
���
���
(pre-set machines only)
59