EN
EVENT
opening
closure
automatic closure
stop during closure
stop during opening
open
closed
programmation
obstacle M1/M2
photo 1!
photo 2!
sensitive edge!
partial opening
automatic partial closure
realignment
phototest error
IND/ELEC error
Malfunctions
This section lists a number of malfunctions which may occur.
SURGE OVERLOAD ALARM
EOL
EO.L.
SAFETY EDGE ALARM
EED
PHOTOCELL ALARM/SAFETY EDGE
EPH
After eliminating the cause of the alarm, to delete all errors simply
press the "DOWN" key or press the SBS (STEPPING) command
Press "UP" to read the following parameters on display.
DISPLAY
Status display (
--, OP, CL, SO,
Maneuvers performed
Motor current 1 [A]
Motor current 2 [A]
24
DESCRIPTION
Gate opening
Gate closing
Gate open with timed reclosure active
Gate stopped during closure
Gate stopped during opening
Gate completely open without automatic reclosure
Gate completely closed
During the programming phase
Motor 1/2 obstacle detected
Photocell 1 tripped
Photocell 2 tripped
Sensitive edge tripped
Partial opening in progress
Gate opening to partial position with timed reclosure activated
Realignment after a manual release
Phototest error detected
Electric lock / gate open light line overload
The motor's current drawdown has increased very quickly
1. The gate has hit an obstacle (M1)
2. There is friction on the leaf of M1
1. The gate has hit an obstacle (M2)
2. There is friction on the leaf of M2
The control unit has received a signal from the safety edge
1. The safety edge has been pressed.
2. The safety edge is not connected correctly
Phototest fail outcome
1. Check the photocell and the safety edge connections
2. Check that the photocells and the safety edg are operating correctly
MEANING
ecc..)
Description of the control unit (
Counter displays alternating the thousands (without dots) and the units (with dots)
Motor current absorption (e.g. 1.5=1.5A)
Motor current absorption (e.g. 1.5=1.5A)
FLASHING LIGHT AND KEY LEDS
2 quick flashes + pause + 1 flash
4 quick flashes + pause, 3 times
2 quick flashes + pause, 3 times
2 quick flashes + pause, 3 times
5 quick flashes + pause, 3 times
3 quick flashes + pause, 3 times
6 quick flashes + pause, 3 times
The display returns to the normal screen.