Key Automation CT202 24 Instrucciones Y Advertencias Para Su Instalación Y Uso página 31

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
Service interval cycle threshold
se.r.
15
(0 = off)
Enabling of continuous flashing indicating service required with se.r.
≠ 0 (only active with gate closed)
se.f.
16
0 = off
1 = on
EL.T.
Electric lock activation time in seconds
17
Water hammer on opening
HA.o.
18
0 = disabled
Water hammer on closing
HA.c.
19
0 = disabled
Motor release from closed/open limit switch. Useful for lightweight
gates
rE.L.
20
0 = off
1 to 10 release levels (1 = minimum release, 10 = maximum release)
High-speed motor start-up
ST.P.
0 = on
21
1 = off
Leaf 1 closing delay with gate open
n
dm.I.
22
0 = Off
1 = 1 to 20 Seconds On
Reset to default values
1= RAY2524/RAY2224
DE.F.
2= REVO2224
23
3= INT24
4= STAR2024
To set the default values: 1) access the advanced programming fun-
ction; 2) select the "dEf" parameter"; 3) activate the modification
mode ("0" on display"); 4) accept the modification (press "MENU"
10
0
2
0
0
0
0
1
1
and hold it down). A countdown should now appear: 49,48...,1
down to "don". Release the key when finished.
EN
x 1000
0
200
cycles
0
1
1
10
s
0
100
*100ms
0
100
*100ms
0
10
0
1
0
20
1
4
31