Emptying the vacuum cleaner waste
container
The vacuum cleaner waste container must
be emptied when it is has filled up to ap-
prox. 3 cm below the upper edge.
1. Switch off the device.
2. Secure the device using the parking
brakes on the steering rollers.
3. Open the lock on the vacuum cleaner
waste container upwards.
4. Pull the vacuum cleaner waste container
out of the device.
5. Empty the vacuum cleaner waste con-
tainer and insert it back into the device in
the reverse order.
Note
The vacuum cleaner waste container can
be lifted at the handle using a crane. Maxi-
mum load for crane transport: 50 kg.
CAUTION
Risk of injury and damage!
Note the total weight of the vacuum cleaner
waste container when transporting with a
crane.
Do not overload the container.
Observe the applicable regulations for lift-
ing with a crane.
Shutting down
Switching off the device
1. Switch off the device at the main switch.
2. Pull out the mains plug.
Finishing operation
1. Switch off the device.
2. Remove the accessory and, if neces-
sary, flush it out with water and allow to
dry.
3. Empty the vacuum cleaner waste con-
tainer, see chapter Emptying the vacu-
um cleaner waste container.
4. Vacuum off the inside and outside of the
device and clean with a moist cloth.
CAUTION
Tipping and slipping of the device
during transport
Risk of injury and damage
When transporting in vehicles, secure the
device against slipping and tipping over ac-
cording to the applicable regulations.
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during
transport and storage.
1. Store the device indoors only.
Care and service
DANGER
Device unintentionally starting / electric
shock
Unintentional starting of the suction motor
can cause injuries. Voltage on electrical
components can lead to an electric shock.
Switch off the device and unplug the mains
plug before performing any work on the de-
vice.
Maintenance intervals / user
No periodic maintenance intervals are
specified for this device. The following
maintenance is to be performed as neces-
sary:
Wash the filter.
Change the filter.
Replace the filter.
Inspection and maintenance work
Have the vacuum cleaner regularly inspect-
ed according to the respective national ac-
cident prevention regulations. Maintenance
work as specified by the manufacturer must
be performed by a technically qualified per-
son at the specified regular intervals and in
English
Transport
Storage
maintenance
7