Micropulse Transducer in a Profile Housing
6

Configuration with the Micropulse Configuration Tool

6.1

Value table for factory setting

Output gradient
Transducer
Rising
BTL7-A...
(output 1)
BTL7-G...
BTL7-C...
BTL7-E...
Falling
BTL7-A...
(output 2)
BTL7-G...
BTL7-C...
BTL7-E...
Tab. 6-1:
Value table for factory settings
NOTICE!
Interference in function
Configuration with the Micropulse Configuration Tool
while the system is running may result in malfunctions.
► Stop the system before configuration.
6.2

Micropulse Configuration Tool

The BTL7-A/C/E/G501-... transducer can be configured
quickly and simply on a PC using the Micropulse
Configuration Tool PC software.
The most important features include:
Online display of the current position of the magnet
Graphical support for setting the functions and curves
Display of information on the connected transducer
Selectable number formats and units for display
Resetting to factory settings is possible
Demo mode without having transducer connected
The PC software and associated
manual can be found in the Internet under
www.balluff.com.
14
english
Unit
Min. value
Null value
V
−0,5
V
−10,5
−10,0
mA
0
mA
3,6
4,0
V
+10,5
+10,0
V
+10,5
+10,0
mA
20,4
20,0
mA
20,4
20,0
6.3
With BTL7-A/C/E/G501-... transducers with connectors
(S32/S115), the communication box must be looped in
between the transducer and controller. The communication
box is connected to the PC via a USB cable.
Connection cable approx. 0.3 m with
S32 or S115 (female) connector
Fig. 6-1: Connecting the communication box with a connector
With a BTL7-A/C/E/G501-...-KA_ _ transducer, the
communication lines La, Lb and GND must be connected
to the USB communication box.
Fig. 6-2: Connecting the communication box with a cable connection
End value
Max. value
0
+10,0
+10,5
+10,0
+10,5
0
20,0
20,4
20,0
20,4
0
−0,5
−10,0
−10,5
0
4,0
3,6

Connecting the USB communication box

USB cable
8-pin
8-pin
USB cable
When reading or writing data via the
Configuration Tool, both LEDs flash green.
Error value
+10,5
+10,5
20,4
3,6
−0,5
−10,5
0
20,4
3,6
Connection cable
approx. 0.3 m with
S32 or S115 (male)
connector
Controller
6-pin
Controller
Connection cable
approx. 0.6 m with