Position Sensing With The Balluff Btl6-V11V - Balluff BTL6-V11V-M-A1-S115 Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL6-V11V-M-A1-S115 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL6-V11V-M _ _ _ _ -A1-S115
Magnetostrictive Linear Position Sensor – Profile Style
6
Device profile (continued)
6.2
Position sensing with the Balluff
BTL6‑V11V‑...
PLL_Sync_out
T
I
START/STOP
T
Start
Fig. 6-1:
Basic signals for position sensing
Fig. 6-1 displays the basic signals used for position
sensing. The sensing cycle starts with PLL-Sync_out
which generates the start pulse. Measurements are taken
between the trailing edge of the start pulse and the trailing
edge of the corresponding stop pulse (see Fig. 6-1).
Time T
is available in the position result register (see
Magnet
Memory address space mapping on page 10).
The PLL_Sync_out time interval must be defined
by the user during startup.
The position of the magnet can be calculated using the
following formula:
(R
– Offset) x Multiplier
Magnet
P
=
Magnet
Divisor
P
The current position of the magnet in µm
Magnet
R
Values for the current position of the magnet
Magnet
in increments (example: result position 1 for
magnet 1)
Offset
Offset zero position in increments
Multiplier
Length of BTL in μm
Divisor
Length of BTL in increments
See configuration guide, calibration data
1)
www.balluff.com
INIT-FRAME T
T
Magnet
,
1)
1)
1)
1)
F
T
T
Stop
Stop N
T
I
T
Start
english
11

Publicidad

Tabla de contenido
loading