Descargar Imprimir esta página

Ingeteam INGEREV Serie Manual De Instalacion Y Uso página 24

Ocultar thumbs Ver también para INGEREV Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Ingeteam
INGEREV GARAGE
3.
Connect the rest of the charging stations as shown in the following figures:
First station
Intermediate station
Final station
Control card jumper
Control card jumper
The jumper of the control card must be removed in all the stations except for the final station on the
communication ring, where it must be installed.
Communication ring:
First station
Intermediate station
Final station
A maximum of 10 units can be interconnected.
24
ABA2017IQM01_A - Installation and Operation Manual