Thread the cabling through and tighten the cable protectors. Leave margin so that the cabling is not
tense.

3.2. Local communication

Follow the instructions below to complete the local connection:
1.
Connect the RS-485 communications card in all the charging stations that make up the communication
ring. It must be inserted into connectors J15 and J17.
2.
Connect the wiring that joins the communications card to the communications card of the following
charging station (see the dark grey cabling in the following figure).
Use a USB to RS-485 converter (not supplied by Ingeteam) to connect the computer to the first station of
the communication ring (white cable in the following figure).
10
Pin
Signal
1
RS-485 B (+)
2
RS-485 A (–)
6
GND
ABA2017IQM01_A - Installation and Operation Manual
INGEREV GARAGE Basic