3.2 Technical data

Feature
Power supply
Ambient temperature
Relative humidity
Degree of protection
Transponder technology
Approvals
Accessories
Feature
Programming key card
Clearing key card
User key
Macros

3.3 Functions

Latchbolt lock operation / self-locking action (= factory setting)
In latchbolt lock operation, the furniture lock is unlocked during the open time of 3 seconds and
locks again automatically once the open time has elapsed (self-locking action).
Deadbolt lock operation (permanent open)
In deadbolt lock operation, the furniture lock is permanently unlocked (permanent open). The
furniture lock is locked by presenting one of the user keys that is authorised for deadbolt lock
operation again.

3.4 Factory settings

Parameter
Open time (duration of unlocking period in latchbolt lock operation)
• The open time can be set to up to 30 seconds at one second intervals
in stand-alone operation
• The open time can be extended to beyond 30 seconds using a macro
with the MDU 110 mobile programming unit with special functions.
Lock type
Value
2 x 1.5 V AAA micro batteries (LR03) alkaline
Type EN92 Energizer
(Häfele Cat. No.: 910.54.986)
0–55°C
10–95% not condensed
IP20
Tag-It, Mifare Classic EV1, Mifare DESFire EV1EV2.
The transponders used for Dialock software applications must be
qualified and encoded by Häfele.
CE, FCC / IC
Description
• Card for granting access authorisations
• Card for clearing access authorisations
• Electronic key
• Different designs are possible: key card, key tag, key fob,
key wristband
• On request
8.3 Adjusting the open time, page 44.
Value
3 seconds
Latchbolt lock operation
31