Wall Mount Installation
:
Note
The installation knockouts numbering are marked on
the back plate.
1. Open WatchIN front cover
(unlock C1, Figure 1).
2. Release internal base (unlock I1, Figure 2).
3. Select mounting installation as follows:
Flat Mounting:
Open knockouts on external base (Figure 3).
• B1 - B4: Wall mounting knockouts
• T1: Back tamper knockout
• W2 / W3: Wires entry knockouts
45° angle Mounting (Left side
mounting):
a. Open knockouts on external base
(Figure 3)
• L1, L2: Left mounting knockouts
• T3: Left tamper knockout
• W5 / W6: Wire entry knockouts
b. Remove tamper spring
c. Replace tamper bracket (Item 1) with
supplied flat tamper bracket (Item 2).
Item 1
d. Insert Tamper lever B onto T5 and T3
and secure screw A (Figure 3)
4. Insert external wires through external base
W2, W3 (Flat Mounting) or W5, W6 (Left
side mounting) (Figure 3).
5. Secure external base to the wall.
6. Insert external wires and tamper wires
through internal base (Figure 4).
7. Secure internal base to external base (lock
I1, Figure 2).
8. Close the front cover (Lock C1, Figure 1)
after wiring and setting DIP switches.
9. Walk test the detector.
Note:
For 45° right side installation use the equivalent units on the external base as follows:
Knockouts Description
Mounting Knockouts
Tamper spring knockouts
Tamper screw anchor
Wiring Knockouts
Figure 1
Figure 3
Tamper
Lever
B
Item 2
A
Figure 4
Left
L1, L2
T1, T3
T5
W5, W6
WatchIN Installation Manual
Figure 2
C1
T6
T1
T3
L1
B1
W5
W6
W3
L2
B4
Right
R1, R2
T2, T4
T6
W7, W8
I1
T5
T4
T2
R1
(not visible)
B2
W9
W2
R2
(not visible)
B3
5