Display
FC 5
Program identification code (ROM)
(this is an example only)
HoLd
Wait...power has just been turned on
PAY/(price)* Pay (flashes alternately with start price if
"FLSH" SETUP option is enabled)
CY
Cycle (followed by two-digit number)
tESt/CYC*
Test cycle selected
FAr
Degrees Fahrenheit
CEL
Degrees Celsius
HEAt
Auxiliary heat enabled
noHt
Auxiliary heat disabled
n
Strt/A
t*
Start amount – flashes briefly before
showing vend price in Setup Mode
Con1/deno*
Coin 1 value – flashes briefly before
showing value of coin 1 in Setup Mode
Con2/deno*
Coin 2 value – flashes briefly before
showing value of coin 2 in Setup Mode
PrE
Prewash segment (1st of 8 segments)
UASH
Wash segment (2nd of 8 segments)
FIL1
First fill (3rd of 8 segments)
FIL2
Second fill (4th of 8 segments)
FIL3
Third fill (5th of 8 segments)
FIL4
Fourth fill (6th of 8 segments)
FIL5
Fifth fill (7th of 8 segments)
FIL6
Sixth fill (8th of 8 segments)
AFIL
Auxiliary fill
bFIL
Warm fill (both hot and cold)
CFIL
Cold fill
bLCH
Add bleach (for supply 2 only)
1Pr
One vend price – all cycles
16Pr
16 vend prices – one per cycle
CHEC/
Test cycle selected (same as tESt/CYC)
CYC*
For
Wash speed forward in test cycle
FrEE
"Free" cycle option
*Display indications separated by a slash (/) represent an alternating display.
F232137
Display Indications for V-Series – Coin
Meaning
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Display
HFIL
Hot fill
Lo
Low water level
n
Ed
Medium water level
HI
High water level
SUP0
No supplies
SUP1
Supply 1
SUP2
Supply 2
SUP3
Supply 3
SUP5
Supply 5 (supply 1 and 2)
SUP6
Supply 6 (supply 2 and 3)
drAI/dISt*
Distribution (load balancing before extract)
(Variable-speed only)
drAI/For*
Drain step (low speed forward in test cycle)
n
SPIn/tI
E*
Reads "SPIn" for one second, then "tI
followed by time for spin
SdLY
Spin coast delay
STOP
Stop routine
donE
Cycle and stop routine have ended
HI 1
Low spin in test cycle (Variable-speed only)
HI 2
High spin in test cycle (Variable-speed only)
bAL/FAIL*
Balance routine failed during test cycle
SHUT/door*
Door not properly closed
CANt/OPEN*
Computer cannot unlock door after five
attempts
FILL/STOP*
Programmed water level not reached after
30 minutes
FULL
The computer detects low water level or higher
when none should be present
dFLt
Drive fault detected (Variable-speed only)
tSFL
Temperature sensor failure or temperature out
of range
bAL?
Special factory balance setup mode
SPC?
Special factory valve flush mode
SPIN
Spin in test cycle (2 speed only)
rEv
Reverse wash speed in test cycle
Table 2
Operation
Meaning
n
E"
9