Operator troubleshooting
Most minor problems can be resolved quickly and easily using the table below.
If problems persist, contact a metabo HPT authorized service center for assistance.
1. Power tool
PROBLEM
Power switch doesn't turn on.
Turn on once, but turn off
automatically.
Nailer doesn't operate
(Power switch ON).
Nailer operates, but no nail is driven.
Weak drive.
Slow to cycle.
Skipping nails.
Intermittent feed.
CHECK METHOD
Low battery charge.
Damaged internal electronics.
Push lever and/or trigger is ON state? Keep push lever and trigger in OFF
Keep no operation over 30 minutes?
(Auto-power off function)
Nailer not enough pressed against
workpiece.
The Nailer is not perpendicular to the
workpiece.
Trigger not enough pulled.
More than 2 seconds pass from push
lever ON to trigger ON (or trigger ON
to push lever ON).
Preventive mechanism activated.
(No nails, or too few fasteners
remaining)
Lock lever(Trigger lock function) is
"ON" position.
Machine is too cold (below 23°F
(-5°C)) or too hot.
Damaged internal electronics.
Magazine is dirty.
Check for a jam.
Driver blade worn or damaged?
Ribbon spring weakened or
damaged?
Nail feeder damaged?
Check for proper nails.
Driver blade worn?
Compressed air pressure has
become low.
Damaged internal electronics.
Check for proper nails.
Nail feeder damaged?
Ribbon spring weakened or
damaged?
Driver blade worn or damaged?
CORRECTION
Charge the battery.
Contact metabo HPT for inspection.
state.
Push and hold power switch more
than 1 second to switch "ON"
Hold nailer fi rmly and press to the
workpiece completely.
Hold the Nailer perpendicular to the
workpiece.
Pull the trigger fi rmly.
Make sure that less than 2 seconds
pass between push lever ON and
trigger ON (or between trigger ON
and push lever ON).
Reload the nails into magazine.
Set Lock lever to "OFF" position.
(Refer to page 20)
Allow the nailer to cool or warm-up
throughly in adequate condition.
Contact metabo HPT for inspection.
Blow and wipe clean the magazine.
Clear a jam. (Refer to page 25)
Contact metabo HPT for inspection.
Replace ribbon spring.
Replace nail feeder.
Use only recommended nails.
Contact metabo HPT for inspection.
Contact metabo HPT for inspection.
Contact metabo HPT for inspection.
Use only recommended nails.
Replace nail feeder.
Replace ribbon spring.
Contact metabo HPT for inspection.