Connecting The Pneumatic System En - Binzel BRS-FP Instructivo De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6 Putting into operation
6.1 Connecting the pneumatic system
The BRS-FP uses cleaned and lubricated compressed air, which is supplied to the integrated distributor block
by means of a maintenance unit.
The supply line required for this purpose has a minimum inner width of 8 mm and is not included in the scope
of delivery.
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance, servicing, assembly,
disassembly and repair work:
• The BRS-FP torch cleaning station must remain without pressure until installation is complete.
NOTICE
• The cleaning capacity of the torch cleaning station depends on operating pressure, number of
Pneumatic motor
Fig. 5
EN - 12
WARNING
revolutions of the motor and atomization of the anti-spatter fluid. Determine the most favorable
adjustment in a test run.
Clamping cylinder
release/clamp
M
Z2
S2
DN (nom. diam.) 6
DN 4
DN 4
4
2
Y2
14
14
14
12
12
1 3
5
Connecting the pneumatic system
Stroke cylinder
backwards/forwards
Z1
S1
Inner width 4
6x1
DN 4
DN 4
4
2
Y1
14
14
12
12
5
1 3
6 bar
BRS-FP
Injector
M
Inner w
6x1
4
2
Y3
14
12
12
1 3
5
Draw in from
bottle

Publicidad