Install and operate unit at least
24 inches from any obstructions in
a clean, well ventilated area. The
surrounding air temperature should
not exceed 100° F. This will ensure
an unobstructed flow of air to cool
compressor and allow adequate space
for maintenance.
Do not locate the
compressor air
inlet near steam, paint spray,
sandblast areas or any other source
of contamination.
NOTE: If compressor operates in a hot,
moist environment, supply compressor
pump with clean, dry outside air. Supply
air should be piped in from external
sources.
TANK MOUNTING
The tank should be bolted into a flat,
even, concrete floor or on a separate
concrete foundation. Vibration isolators
should be used between the tank leg
and the floor. Model MP367700AJ
isolator pads are recommended for
horizontal units. Model MP345700AJ
isolator pads are recommended for
vertical units. When using isolator
pads, do not draw bolts tight. Allow
the pads to absorb vibrations. When
isolators are used, a flexible hose or
coupling should be installed between
the tank and service piping.
Failure to properly
install the tank can lead
to cracks at the welded
joints and possible bursting.
PIPING
Never use plastic
(PVC) pipe for
compressed air. Serious injury or
death could result.
Any tube, pipe or hose connected to
the unit must be able to withstand the
temperature generated and retain the
pressure. All pressurized components
of the air system must have a pressure
rating higher than or equal to the
200 psi for two-stage compressors or
150 psi for single stage compressors
ASME safety valve setting.
Incorrect selection and installation of
any tube, pipe or hose could result in
bursting and injury. Connect piping
system to tank using the same size
fitting as the discharge port.
Chart 1: Minimum Pipe Size for
Compressed Air Line (in inches)
Length Of Piping
System (in feet)
CFM
25
50
10
1/2
1/2
20
3/4
3/4
40
3/4
1
60
3/4
1
100
1
1
INSTALLING A SHUT-OFF VALVE
A shut-off valve should be installed
on the discharge port of the tank to
control the air flow out of the tank.
The valve should be located between
the tank and the piping system.
Never install a
shut-off valve
between the compressor pump
and the tank. Personal injury and/
or equipment damage may occur.
Never use reducers in discharge
piping.
When creating a permanently installed
system to distribute compressed air,
find the total length of the system and
select pipe size from the chart. Bury
underground lines below the frost line
and avoid pockets where condensation
can gather and freeze.
Pump
Pressure
Gauge
Safety Valve
Access
Figure 1 - Vertical Unit Identification
3
Apply air pressure to the piping
installation and make sure all joints are
free from leaks BEFORE underground
lines are covered. Before putting the
compressor into service, find and repair
all leaks in the piping, fittings and
100
250
connections.
3/4
3/4
WIRING
3/4
1
1
1
connections must be performed by
1
1
a qualified electrician. Installations
1
1-1/4
must be in accordance with local
and national codes.
damage will result from inadequate
wiring.
Wiring must be installed in accordance
with National Electrical Code and local
codes and standards that have been set
up covering electrical apparatus and
wiring. These should be consulted and
local ordinances observed. Be certain
that adequate wire sizes are used, and
that:
1. Service is of adequate ampere
rating.
2. The supply line has the same
electrical characteristics (voltage,
cycles and phase) as the motor.
Air Filter
HS5180
All wiring
and electrical
Overheating, short
circuiting and fire
Discharge Tube
Beltguard
Motor
Pressure
Switch
Discharge
Port
Drain Valve
www.campbellhausfeld.com