Technical Data

Measured variable
Contact temperature
measuring range
Contact temperature
accuracy
Ambient temperature
measurement range
Degree of protection
Power supply
Operating time
Operating conditions
Storage conditions
Radio module
operating data
Dimensions
(W x H x D)
Probe
Weight
Subject to technical changes without notice. 20W05
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be collected
separately for disposal according to the European
Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=AJI
ThermoControl Air
Contact temperature
Ambient temperature
0°C ... 85°C
± 1°C
0°C ... 300°C
IP 66
1 x 1.5V LR6 (AA)
approx. 4 hours
Probe: 0°C ... 85°C, Charger: -10°C ...
50°C, max. humidity 85% rH,
no condensation, max. working altitude
2000 m above sea
-10°C ... 60°C, max. humidity 85% rH,
no condensation
Bluetooth LE 4.x interface; Frequency
band: ISM band 2400–2483.5 MHz,
40 channels; Transmission power: max.
10 mW; Bandwidth: 2 MHz; Bit rate:
1 Mbit/s; Modulation: GFSK/FHSS
168 x 24 x 40 mm
90 mm, ø 5,9 mm
80 g (incl. battery)