Bradley 400 Serie Manual Del Usuario página 22

Divisiones para baños con revestimiento de polvo y de acero inoxidable para montaje en el piso con soporte superior
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Powder Coated & Stainless Steel Restroom Partitions, Floor-Mounted with Overhead Brace — Series 400
9b
Stainless Steel Flat Hinge (Optional)
See Step 1 for instructions on
laying out pilaster plumb line.
From the highest point in the room, measure
A
12" (305mm) and 68-3/8" (1737mm) from the floor .
Use a level to transfer these marks to the pilaster
plumb line .
Position the bottom of the bottom flat hinge on the
12" (305mm) mark and center on the pilaster plumb
B
line . Using the flat hinge as a template, mark the
hole locations on the wall . Remove the flat hinge and
drill a Ø1/4" hole (minimum 2" [51mm] deep) at each
hole location .
Position the top of the top flat hinge on the
68-3/8" (1737mm) mark and center on the pilaster
C
plumb line . Using the flat hinge as a template, mark
the hole locations on the wall . Remove the flat hinge
and drill a Ø1/4" hole (minimum 2" [51 mm] deep) at
each hole location .
Insert plastic anchors in all holes and secure the flat
D
hinges to the wall with #10 x 2" stainless flat head
screws provided .
E
See Step 9, D thru F for instructions on attaching the
door to the hinge .
22
3/21/2018
Pilaster Plumb Line
Floor
Bradley • HDWT-INSTR-009 Rev K; ECN 17-14-007
Installation
68-3/8"
(1737mm)
12"
(305mm)