Installation
4b
Alcove Brackets to Pilaster
Layouts that use continuous aluminum brackets for pilaster and panel connections will use stirrup brackets for alcove connections.
Continuous stainless steel brackets use continuous alcove brackets.
Refer to the submittal drawing for the layout location of each alcove pilaster.
Measure down from the top of
A
the pilaster and place a mark at
dimensions shown for the respective
bracket situation .
Stirrup: Position the center of each
B
bracket at the marks made in Step A .
Continuous: Center the bracket
between each mark made in Step A .
Using the bracket as a template,
C
mark the hole locations on the
pilaster . Remove the bracket and drill
Ø3/16" holes through the pilaster at
each location .
Secure the bracket(s) to the
D
pilaster using the #14 x 5/8" screws
(stainless on continuous) provided .
5
Pilaster Mounting Hardware
A
This view is an example only . Refer to your submittal drawings to determine placement of the anchors on the pilaster
centerline for your application . Typical anchor centers are measured 1" (25mm) in from each edge of the pilaster (except 3"
pilasters where only one anchor is used) .
3"
(76mm)
Drill Ø5/16" holes (min 2" [51mm] deep) in
B
the floor and make sure the holes are free
of dirt and debris .
C
Insert plastic anchors into the holes and
fasten the "L" brackets to the anchors
using the #14 x 2" screws provided .
Bradley • HDWT-INSTR-009 Rev K; ECN 17-14-007
Powder Coated & Stainless Steel Restroom Partitions, Floor-Mounted with Overhead Brace — Series 400
17-7/16"
(443mm)
63-7/16"
(1611mm)
Pilaster Centerline
38"
(965mm)
Stirrup
68-15/16"
(1749mm)
22"
(559mm)
3/21/2018
Continuous
11-15/16"
(302mm)
28"
6"
(711mm)
(152mm)
9