4
Stirrup Brackets to Pilaster (Standard)
Refer to the submittal drawing to locate the split
dimension and layout location of each marked pilaster.
17-7/16"
(443mm)
63-7/16"
(1611mm)
4a
Continuous Brackets to Pilaster (Optional)
Refer to the submittal drawing to locate the split
dimension and layout location of each marked pilaster.
Brackets are used as templates but since the hole patterns
may be different, the brackets may not be interchangeable.
Continuous stainless steel bracket shown.
Dim . "A"
Dim . "B"
Stainless
11-15/16"
69-15/16"
Steel
(302mm)
(1749mm)
Bracket
Aluminum
11-11/16"
69-3/16"
Bracket
(297mm)
(1749mm)
8
C L
C L
"A"
"B"
3/21/2018
Measure 17-7/16 (443mm) and 63-7/16" (1611mm) down from
A
the top of each pilaster and place a mark on the pilaster split
centerline .
Pilaster shown is for reference only. Actual pilaster varies
depending on application.
Place stirrup brackets at each established level line . Center
the bracket opening on the pilaster split centerline . Using the
B
bracket as a template, mark the hole locations on the pilaster .
Remove the bracket and drill a Ø3/16" pilot hole (through
inside face of pilaster only) at each location .
C
Secure the stirrup brackets to the pilasters using the #14 x 5/8"
screws provided .
Measure down from the top of the pilaster and
A
place a mark on the pilaster split centerline
at dimensions "A" and "B" for the respective
bracket (see table at left) .
Pilaster shown is for reference only. Actual
pilaster varies depending on application.
Place the continuous bracket between each
established level line . Center the bracket
B
opening on the pilaster split centerline . Using
the bracket as a template, mark the hole
C L
locations on the pilaster . Remove the bracket
and drill a Ø3/16" pilot hole (through inside
face of pilaster only) at each location .
Secure the continuous bracket to the
C
pilasters using the #14 x 5/8" stainless
screws provided .
Bradley • HDWT-INSTR-009 Rev K; ECN 17-14-007