Telescoping And Wall Hung Pilasters - Bradley 400 Serie Manual Del Usuario

Divisiones para baños con revestimiento de polvo y de acero inoxidable para montaje en el piso con soporte superior
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
6c
Telescoping Pilasters (Optional)
Mounting channels are used as templates but may not be interchanged because the hole patterns may be different.
Wall: From the highest point in the room, measure 12-1/8"
(308mm) up from the floor and transfer this level line to
the pilaster plumb line . Place the bottom of the mounting
A
channel at the level line and center the channel opening on
the plumb line .
Pilaster: Measure 12-5/16" (313mm) down from the top
of the pilaster and place a mark on the pilaster centerline .
Place the top of the mounting channel at this mark and
center the channel opening on the centerline .
Wall: Using the mounting channel as a template, mark the
hole locations and remove mounting channel . Drill a Ø5/16"
B
hole (min 2" [51mm] deep) at each hole location .
Pilaster: Using the mounting channel as a template, mark
the hole locations and remove the mounting channel . Drill a
Ø1/4" hole through the pilaster .
Telescoping Pilaster at Wall
Mounting Channel
Pilaster Plumb Line
Floor
Bradley • HDWT-INSTR-009 Rev K; ECN 17-14-007
Powder Coated & Stainless Steel Restroom Partitions, Floor-Mounted with Overhead Brace — Series 400
Telescoping
Channel
Specified
Dimension
12-1/8" (308mm)
to Bottom of
Channel (Highest
Point in Floor)
Wall: Insert the plastic anchors in all holes and secure
the mounting channel to the wall with the #14 x 2" screws
C
provided .
Pilaster: Secure the mounting channel to the pilaster with
the #10-24 x 3/4" barrel nuts and the #10-24 x 1" shoulder
screws provided .
Slide the telescoping channel over the mounting channel .
D
Refer to the submittal drawings and adjust the width to
meet the specified dimension .
Using the holes in the telescoping channel as a template,
E
drill Ø3/16" holes through the mounting channel . Secure the
telescoping channel to the mounting channel with the
#14 x 5/8" screws provided .
Wall, Pilaster or Panel
Mounting Channel
Telescoping Pilaster at Pilaster
12-5/16"
(313mm)
Mounting Channel
3/21/2018
Pilaster
Centerline
13

Publicidad