Prepare The Site - Kohler K-8034 Guia De Instalacion

Ocultar thumbs Ver también para K-8034:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2x6
Power Data Supply
2x6 Stud Cavity
Outlet

2. Prepare the Site

The PDS is designed to fit within a service closet or 2x6 stud
cavity with access panel. The service closet or access panel must
be located less than 30 ft (9.14 m) from the overhead rain panel.
Recommended maximum distance is 25 ft (7.62 m).
If mounting boards are required, they should be positioned to
allow adequate surface area to attach the PDS via the existing
mounting holes on both ends of the PDS box.
Install a 120 V GFCI/RCD electrical outlet within the service
closet or 2x6 stud framing, within 24" (61 cm) of the PDS. Locate
the outlet in close proximity to the PDS to allow enough cable to
create a drip loop.
Note: For hardwire installations, order Service Kit #1078031.
1078520-2-A
Position
to far left.
6" (15.2 cm) Min
Drip Loop
8
Mounting Board
8-1/4" (21 cm)
Kohler Co.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

K-8038

Tabla de contenido