MAINTENANCE
COMMON FAULT AND MAINTENANCE
Problem
and Code
A - No energy power
B - The Emergency Key is not in the
System
correct place
not working
C - The inverter is not properly
connected or it has a fault.
D - Turn off
A - Loose emergency key
Treadmill
sudden
stoppage.
B - Problem in the system
Button
Malfunctions Broken buttons
A -Poor cable communication
E-01
B - Broken Console
C - Broken Inverter
D - Broken motor controller
A - Broken Motor Cable
or Broken Motor
E-02
B - Bad motor wire connections with
the controller or bad controller.
A - Incorrect installation of the
light sensor
B - Problem on the light sensor
E-03
C - Poor connection between the
light and the controller
D - Poor controller
A - Damaged controller
E-05
B - Damaged motor
A - The sensor cable communication
LED Display
is not well connected or the sensor is
with no
broken
pulsation
signal
B - Broken console connector
Cause
41
Solution
Connect the power cord into an outlet
and set the switch ON.
Change the emergency key position
Both check and connect the inverter or
replace it.
Check if the outlet is working
correctly
Replace the Emergency Key
Contact authorized repair points
1 - Replace buttons and cables
2 - Replace the motherboard
3 - Replace the console
Make sure that all connections are fully
inserted. Replace any damaged cable if
needed.
Replace the console
Replace the inverter
Replace the controller
Replace the motor
Check and reconnect the cables
or replace the controller
Both check and assemble it again
Replace the light sensor
Check it and reconnect it
Replace the controller
Repalce the controller
Replace the motor
Both check and connect the cables again
or replace the sensor cable
Replace the console