Example of Parameter Settings
Key sequence
Indicator
In approx. 1s
Note 1: To cancel the set value, press the Mode Key instead. The parameter will be displayed.
Note 2: There are parameters that cannot be changed while the Inverter is in operation. Refer to the
list of parameters. When attempting to change such parameters, the data display will not change by
pressing the Increment or Decrement Key.
Cancels
set data
In approximately 1s
Display example
Explanation
Power ON
Press the Mode Key repeatedly until the PRGM
indicator is lit.
Use the Increment or Decrement Key to set the
parameter number.
Press the Enter Key.
The data of the selected parameter number will
displayed.
Use the Increment or Decrement Key to set the data.
At that time the display will flash.
Press the Enter Key so that the set value will be
entered and the data display will be lit. (see note 1)
The parameter number will be displayed.