pH value
electrical conductivity *
settleable solids **
total suspended solids *** < 50 mg/l
Hydrocarbons
Chloride
Sulphate
Calcium
Total hardness
Iron
Manganese
Copper
Active chloride
free of bad odours
* Maximum total 2000 µS/cm
** Test volume 1 l, settling time 30 min
*** no abrasive substances
Safety instructions
PROPOSITION 65
WARNING
The burner exhaust from this product con-
tains chemicals known to the State of Cal-
ifornia to cause cancer, birth defects or
other reproductive harm.
– Please follow the national rules and
regulations for fluid spray jets of the re-
spective country.
– Please follow the national rules and
regulations for accident prevention of
the respective country. Fluid spray jets
must be tested regularly and the results
of these tests must be documented in
writing.
– The heating appliance of the machine is
an ignition plant. All national laws and
regulations about heating systems must
also be followed.
– The appliance/accessories must not be
modified.
8
6,5...9,5
Conductivity
fresh water
+1200 µS/cm
< 0,5 mg/l
< 20 mg/l
< 300 mg/l
< 240 mg/l
< 200 mg/l
< 28 °dH
< 50 °TH
< 500 ppm (mg
CaCO
/l)
3
< 0,5 mg/l
< 0,05 mg/l
< 2 mg/l
< 0,3 mg/l
EN
Safety Devices
Safety devices serve for the protection of
the user and must not be put out of opera-
tion or bypassed with respect to their func-
tion.
Pressure switch
The pressure switch turns the device off
when the handgun is closed and switch on
when the handgun is opened.
Safety valve
– The safety valve opens in case of ex-
cessive pressure in the boiler or if the
overflow valve or the pressure switch is
broken.
– The safety valve is set by the manufac-
turer and sealed. Setting only by cus-
tomer service.
Water shortage safeguard
The water shortage safeguard prevents the
burner to be turned on when there is water
shortage.
Temperature stop for exhaust gases
The temperature stop switches off the ma-
chine when the waste gases have reached
very high temperatures.
Winding protection contact
The winding protection contact in the motor
winding of the pump drive switches off the
engine when there is a thermal overload.
Safety catch
The safety catch on the trigger gun pre-
vents the appliance from being switched on
unintentionally.
Start up
WARNING
Risk of injury! Appliance, accessories, sup-
ply lines and connections must be in fault-
free condition. If they are not in a perfect
state then the appliance must not be used.
– 3