WARNING: in order to adjust combustion and thermal capacity correctly, the fumes must be analyzed using specific instru-
ments. Combustion and thermal capacity must be adjusted simultaneously, making sure that the values read are correct and
in any case, that they comply with the safety regulations in force.
THIS OPERATION MUST BE PERFORMED BY PERSONNEL WHO ARE PROFESSIONALLY QUALIFIED
AND AUTHORIZED BY ECOFLAM BRUCIATORI S.p.A..
The Landis control box starts the fan and begins the pre-purging of the combustion chamber. The air pressure switch
controls the correct operation. At the end of the pre-purging phase, the ignition transformer cuts-in followed by the
opening of the gas valves. In case of missed ignition or accidental shutdown, the ionisation probe cuts-in and set the
burner in lockout mode within the safety time.
Gas pressure swi ch
Mo or
Air pressure swi ch
Transformer
Gas valve
High flame ON/OFF
Flame de ec ion
Lock ou
LANDIS & STAEFA SQN 31 251A2700 AIR DAMPER MOTOR
MANUAL RELEASE
SWITCH
CALCULATION OF WORKING OUTPUT OF THE BURNER
To calculate the burner's working output, in kW, proceed as follows:
- Check at the meter the quantity of supplied litres and the duration,
in seconds, of the reading, then calculate the burner's output through
the following formula:
CONTROL BOXES LANDIS & STAEFA LGB22
2
1
lamp
Remove cover to gain access to the adjusting cams.The cams are to be adju-
sted through the suitable key provided for. Description:
I
- Limit switch for air damper "High Flame" position adjustment
II - Limit switch for the air damper position at burner's shut down
III - Limit switch for air damper "Low Flame" position adjustment
V - Limit switch "NOT USED".
LB1684 BLU 500.1 ÷ 1200.1 PR Low NOx
3
4
1
2
5
3
4
6
5
6
(Max. power)
(Min. power)
pag.11
Description
pressure swi ch con rol ime-ou
ime-ou for air pressure confirma ion
prewashing ime
safe y ime
preigni ion ime
ime-ou
o enable fuel 2nd valve
e x f = kW
s
B
9"
3"
30"
3"
3"
8"
e =
Litres of gas
s =
Time in seconds
G20 = 34,02
G25 = 29,25
f
G30 = 116
G31 = 88