Victron energy Skylla-i Control GX Manual De Instrucciones página 26

Ocultar thumbs Ver también para Skylla-i Control GX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

E17
Charger overheated
E18
Charger over-current
E20
Maximum Bulk-time
exceeded
E34
Mains over-current
116
Internal error
(calibration data lost)
CFG
Configuration problem
NC
No connection
Error will reset after charger has cooled down.
If error persists, check the ambient temperature
and check for obstructions near the air inlet and
outlet holes of the charger cabinet.
Check manual for mounting instructions with
regard to cooling.
The charge-circuit is damaged.
Disconnect charger from all power-sources, wait
3 minutes, and power up again.
If error persists--> disconnect charger from
power sources and call service.
This error can only occur when the MAX bulk-
time protection is active (see paragraph 8.10).
This error is generated when the battery-
absorption-voltage is not reached after 10 hours
of charging.
For normal house-hold solar installations it is
advised do de-activate the MAX bulk-time
protection.
The mains current has exceeded 20A. This error
could be generated during an internal system
fault.
Disconnect the charger from all power-sources,
wait 3 minutes, and power-up again. If the error
persists--> call service.
Disconnect the charger from all power-sources,
wait 3 minutes, and power-up. If error persists-->
disconnect charger from power sources and call
service.
The control panel detected more than one Skylla-
in the VE.Can network with the same device
instance. It is not possible to connect one control
panel to multiple Skylla-i chargers. See the
chapter titled 'Multiple Skylla-i's and Control
panels in one VE.Can network'.
The control panel cannot connect to a Skylla-i in
the VE.Can network.
5

Publicidad

Tabla de contenido
loading

Tabla de contenido