26
LED indica-
Meaning
tor
Red LED indicator flashes (2 times per
second).
Red LED indicator flashes (1 times per
second).
Yellow LED indicator flashes (1 time
per second).
Brief lighting up of all LED indicators.
Parameter assignment
Differing to the existing standard programs,
the AccuTec screwdrivers can be freely pro-
grammed in some ranges. To realize these
special solutions, an additional PC program is
required for assignment of the parameters.
Afterwards, the data can be transferred to the
screwdriver with the programming adapter.
The current software can be downloaded
from FEIN via the Internet under
www.fein.com. It can be found in the coun-
try-specific AccuTec section. A link to this
section is provided on the included USB card
of the separately available programming
adapter.
We recommend that you regularly keep the
firmware on your AccuTec screwdrivers up-
to-date.
Explanation
The machine is overheated, the over-
temperature protection has
responded. After cooling down, the
machine is ready for operation again. If
the over-temperature protection
responds several times briefly after
each other, have the power tool
checked by the after-sales service.
The battery type is not suitable for this
screwdriving application.
Recommendation: For soft screw-
driving applications at high torque, use
a battery with higher capacity.
The cordless screwdriver switches to
the Energy Saving Mode.