O Peration With Gas Supply Iden; Checking The Supply Pressure; Primary Air Regulation - Giorik CG720T Manual De Instalación Y Funcionamiento

Cocinas de gas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENG
MODEL
Power supply
Electrical power consumption
Frequency
ISO 7/1 Fitting
Hob burners
Burner 4 kW
Burner 8 kW
Hob thermal power
Oven Type
Max oven thermal power
Nominal thermal power
Category
Construction type
G20 Natural Gas Pressure
G30/G31 LPG Pressure
Overall gas consumption (calculated with calorific value less than (Hi) 15°C and 1013
mbar):
G20 Natural Gas
G30 LPG
4. OPERATION WITH GAS SUPPLY IDENTICAL TO THE ONE AVAILABLE
Check if the indications on the data plate correspond to gas used. Also verify compliance
with the information given below.
4.1 Check the supply pressure
The supply pressure can be measured with a "U" gauge or
electronic-type gauge with minimum gradations of 0.1 mbar.
Unscrew screw "A" from tapping point "B".
Position the gauge.
Operate the unit and check that the pressure is compliant
with the data plate: otherwise, find out why it differs.
Replace and tighten the screw to seal the tapping point
4.2 Primary air regulation
The primary air is properly regulated if the flame stability is
ensured or, in other words, if there are no breaks in the flame
with the burner cold and if there is no backfiring with the
burner hot.
The distance required for regulating the primary air is shown in
the figure to the right and indicated in table B (pages. 52-53).
Unscrew the injector using a spanner and install the required
injector: check the exact air distance, "A".
16
20T
40T
20G
40G
V
kW
Hz
Ø
No.
2
4
No.
1
2
No.
1
2
kW
12
24
-
kW
kW
12
24
mbar
mbar
m3/h
1,27
2,54
Kg/h
0,95
1,89
CG7....
60T
40F
60F
60H
60G
1/2"
6
4
6
3
2
3
3
2
3
36
24
36
GAS
8
8
36
32
44
II 2H3+
A1
20
28-30/37
3,81
3,39
4,66
4,87
2,84
2,52
3,47
3,63
40E
60E
400-3N
6
6
50-60
6
4
6
3
2
3
3
2
3
36
24
36
ELE
10
46
24
36
2,54
3,81
1,89
2,84

Publicidad

Tabla de contenido
loading

Tabla de contenido