ImporTAnT pArTs

IMPoRTanT PaRTs of YoUR IfIll oXYGen CYlInDeR

1
PD1000A series
PD1000A Series
1.
C annula Fitting– Use this fitting to attach the cannula to your iFill
cylinder.
2.
R otary Selector– Use this to select your prescription setting.
3.
O xygen Fill Connection– Use this connection to attach the cylinder
to the DeVilbiss iFill Personal Oxygen Station. NOTE–Your iFill
oxygen cylinder can only be filled with the DeVilbiss iFill
Personal Oxygen Station.
4.
O xygen Contents Gauge– Indicates the remaining pressure in the
oxygen cylinder. When this gauge falls into the red section, you
should switch to a new cylinder.
5.
H ydrostatic Test Date– Contact your homecare provider or the
cylinder manufacturer for details.
6.
H igh-Pressure Oxygen Cylinder– Portable oxygen delivery tank
with labeling. Refer to next page for label verbiage.
7.
P ulseDose Indicator– Either green or red light illuminates
each time the unit pulses oxygen.
N ormal Battery Indicator– A flashing green light indicates that
there is sufficient battery power.
8.
L ow Battery Indicator– A flashing red light indicates that there
are 4 - 8 hours of battery life remaining. The low battery
indication time may be reduced when using NiMH batteries.
8
7
2
9 (on top)
3
4
5
6
2
1
(on rear)
3
535-CF series
C hange Battery Indicator– A constant red light indicates that
the battery should be changed immediately. Unit can be used
only in continuous flow mode until new batteries are installed.
9.
B attery Door– Use only a standard "AA" Alkaline or NiMH
batteries.
535-CF Series
1.
C annula Fitting– Use this fitting to attach the cannula to your iFill
cylinder.
2.
R otary Selector– Use this to select your prescription setting.
3.
O xygen Fill Connection– Use this connection to attach the cylinder
to the DeVilbiss iFill Personal Oxygen Station. NOTE–Your iFill
oxygen cylinder can only be filled with the DeVilbiss iFill
Personal Oxygen Station.
4.
O xygen Contents Gauge– Indicates the remaining pressure in the
oxygen cylinder. When this gauge falls into the red section, you
should switch to a new cylinder.
5.
H ydrostatic Test Date– Contact your homecare provider or the
cylinder manufacturer for details.
6.
H igh-Pressure Oxygen Cylinder– Portable oxygen delivery tank
with labeling. Refer to next page for label verbiage.
EN
A-535-CYL
5