Cylinder Labeling Verbiage

THIS CYLINDER IS TO BE USED WITH THE D
CYLINDER CONTAINS 93+/-3% OXYGEN PRODUCED BY THE DeVILBISS iFILL PERSONAL OXYGEN
STATION USING A PRESSURE SWING ADSORPTION PROCESS.
OXYGEN CYLINDERS FILLED BY THE DeVILBISS iFILL PERSONAL OXYGEN STATION SHALL BE USED FOR PERSONAL USE ONLY.
"NOT TO BE FILLED FOR RESALE"
WARNING: HIGH PRESSURE OXIDIZING GAS VIGOROUSLY ACCELERATES COMBUSTION.
CAUTION: For medical applications. Use only as directed by a licensed practitioner. Uninterrupted use of high concentrations of oxygen over a
long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful.
CAUTION: DO NOT HANDLE CYLINDER OR USE CONTENTS UNTIL YOU ARE TRAINED TO USE CYLINDER AND CONTENTS,
INCLUDING EMERGENCY PROCEDURES.
CAUTION: IMPROPER FILLING OR ABUSE OF THIS CYLINDER, OR FAILURE TO HEED THIS CAUTION MAY CAUSE SERIOUS INJURY
OR LOSS OF LIFE. DO NOT ALTER OR MODIFY CYLINDER OR RELATED COMPONENTS. KEEP OUT OF THE REACH OF CHILDREN.
Secure cylinder during storage and use. No smoking in cylinder area. Turn the regulator or conserver off after each use and when empty. Use in
accordance with the DeVilbiss iFILL Personal Oxygen Station instruction guide. Cylinder temperature should not exceed 130°F (54°C). Keep
away from heat, flame and spark. Do not drop.
"Use No Oil or Grease". KEEP CYLINDER, ALL EQUIPMENT AND CONNECTIONS FREE OF OIL AND GREASE TO AVOID VIOLENT
IGNITION.
TRANSFILLING OF THIS GAS IS PERFORMED BY THE D
Cylinders that have been refinished and/or exposed to elevated temperatures must be hydrostatically tested before filling. Do not use caustic
paint stripper or corrosive cleaners. Aluminum cylinders subject to the action of fire or heated to temperatures in excess of 350°F (177°C) must
be withdrawn from service and condemned by trained personnel. Valve and safety relief devices must be removed and replaced by trained and
authorized personnel. Do not alter or modify this cylinder in any way.
DO NOT REMOVE THIS PRODUCT LABEL
Not for Commercial Resale
ALUMINUM HIGH PRESSURE GAS CYLINDER
Improper use, filling, storage, or disposal may cause personal injury, death, or property damage. Do not alter or modify this cylinder or valve in any way.
Do not use caustic or corrosive cleaners. Never fill this cylinder unless it has been hydrostatically tested. Only trained personnel should fill or service the
cylinder. Only trained personnel should replace valves and pressure relief devices and only with the complete assemblies containing the proper burst disc
rating supplied by the valve manufacturer. Always secure cylinder in a cool dry area, out of reach of children. Do not expose filled cylinder to
°
(54°C)
temperatures above 130
F
to elevated temperatures must be hydrostatically tested prior to refilling. Do not remove, alter, or obscure this warning label. Proper cleaning of cylinder,
valve, and components is required before filling with oxidizing gasses such as oxygen and nitrous oxide.
Service, maintain and inspect cylinders in accordance with C.G.A. pamphlet C-1, C-6.1, G-4, G-4.1, G-4.3, P-1, P-2, P-2.5, P-14, and G-8.2 available
from the CGA at ph. 703-788-2700 or web: www.cganet.com
6
A-535-CYL
VILBISS iFILL PERSONAL OXYGEN STATION. THIS
e
DeVilbiss Healthcare LLC
100 DeVilbiss Drive
Somerset PA 15501
WARNING
. Cylinders exposed to fire or heat in excess of 350
PIPER METAL FORMING CORPORATION
NEW ALBANY, MS
www.piperimpact.com
VILBISS iFILL PERSONAL OXYGEN STATION ONLY.
e
°
177°C)
F (
must be condemned. Cylinders refinished or subjected
MADE IN U.S.A.