Abicor Binzel MT 452 W Instrucciones De Servicio página 34

Mig/mag antorcha de soldadura
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6 Putting into operation
6.2.2 PA liner
1
10
9
1
Wire feed hose
2
Central plug
3
Union nut
4
Wire feed unit
Fig. 4
Shortening the PA liner
EN - 12
6 Cut off the excess length of the guide spiral liner (8) flush with the
torch neck (2) or the tip adaptor (1).
7 Unscrew spigot nut (6) and pull out guide spiral liner (8).
8 Sharpen the spiral guide liner beginning to an angle of approx. 40° and
debur the edge.
9 Slide sharpened guide spiral liner (8) through the wire feed hose (3) up to
the holder nipple (7).
10Screw down union nut (6) and tighten with multiple wrench (5).
11 Screw in contact tip (11) and attach gas nozzle (10).
NOTICE
• New, as yet unused PA liners have to be abridged to the actual length of
the cable assembly.
• For PA liners with an outer diameter of 4.00 mm, the capillary tube in the
distance adaptor must be replaced with a guide tube.
• We recommend that you sharpen the PA liner to an angle of 40° before
assembly using the ABICOR BINZEL sharpener.
PA liners = for aluminium, copper, nickel and stainless steels
2
40 °
8
5
ABICOR BINZEL
6
Guide tube
7
O-ring
3
7
6
Cutter
8
9
10 ABICOR BINZEL
MT/AUT/AUT RAB
4
5
Clamp nipple
PA liner
Sharpener

Publicidad