Floor and walls
The floor on which the appliance is placed must have
sufficient load bearing capacity. For the appliance
weight: see the appendix "Technical data".
Protect a flammable floor from heat radiation
by means of a fireproof protective plate. See
the appendix "Distance from combustible
material".
Remove combustible material such as
linoleum, carpets/rugs and similar materials
below the fireproof protective plate.
Keep enough distance between the appliance
and combustible materials such as wooden
walls and furniture.
The connecting tube radiates heat too. Ensure
that there is sufficient distance or a shield
between the connecting tube and combustible
material.
The rule of thumb for a single-walled tube is a
distance of 3x the diameter. If a lining shell is
fitted around the tube, a distance of 1x the
diameter is permissible.
Carpets and rugs must be at least 80 cm away
from the fire.
Protect a flammable floor from possible falling
ash in front of the fire with the aid of a fireproof
protective plate. The protective plate must
comply with national standards.
For the dimensions of the fireproof protective
plate: see the appendix "Distance from
combustible material".
For further requirements in connection with fire
safety: see the appendix "Distance from
combustible material".
6
Product description
1. Door
2. Bolt
3. Air control scraper
4. Ashtray
5. Adjustable leg
6. Flue gas connection (closed)
Features of the appliance
The appliance is supplied with height-adjustable
legs.
The appliance can be connected to the chimney at
the side, at the rear or at the upper side. A
connection collar that can be ordered separately is
necessary for connecting on the upper side.
An attachment with the designation 5T, which
functions as a heat exchanger, is available for the
appliance. See "Appendix 2: Dimensions" for the
dimensions of the attachment 5T. Via this
attachment, the appliance can be connected at the
side or on the upper side. The connection collar