SERVICING
For any repairs use only the Service Centres recommended by the manufacturer and insi-
st that only original spares be used.
Non-observance of the above could prejudice the safety of the appliance.
If your refrigerator does not work, or if it does not work properly, check these points befo-
re making a Service call.
FAULT
a) Compressor not
functioning
b) Compressor functioning
but not refrigerating
c) Compressor functioning
for short periods
d) Compressor working for
long periods, or all the
time
e) Freezer compartment not
sufficiently cold
After connecting the appliance to the mains, the refrigerator might not function even thou-
gh the green light (1) on the facia is on (see fig.2). This mean the appliance is defrosting.
Resume normal operation when defrosting is completed.
REVERSING THE OPENING OF THE DOORS (see fig. 3)
1) It is advisable to lean the refrigerator at an angle of about 45°, since it is necessary to
work on the bottom of the appliance in order to remove the lower hinge.
2) Remove the plinth, if fitted.
3) Remove the lower hinge (and relative washers), by loosening screws A as shown in
the figure.
4) Remove the lower door.
5) Remove the middle hinge (and relative washers), by loosening screws B as shown in
the figure 3. Models with the upper tall door (fig. 3c – inside upper portion of the top door),
before removing screws that fix the central hinge (between fridge and freezer door) open
24
CAUSE
- Plug not inserted
- Plug wire loose
- No electricity
- Various
- Various
- Ambient temperature
too warm
- Thermostat at maximum
setting
- Excessive use of freezer
compartment
- Ambient temperature too
low or too high
- Other reasons
REMEDY
- Insert the plug
- Check the plug
- Wait for the supply to be
returned
- Call in the refrigeration
engineer
- Call in the refrigeration
engineer
- Turn the thermostat knob
anticlockwise
- Follow the manufacturer's
recommendations
- Functionong is guaranteed
when the ambient
temperature is between +10°
and + 38÷43°C
- Call in the refrigeration
engineer